Pittman, Ella, Martin-Flores, Manuel, Mosing, Martina ORCID: https://orcid.org/0000-0002-6190-5642, Lorenzutti, Augusto Matías ORCID: https://orcid.org/0000-0002-9799-4499, Retamales, Jaime, Staffieri, Francesco ORCID: https://orcid.org/0000-0002-2085-376X, Adler, Andy, Campbell, Mark and Araos, Joaquin (2022) Preliminary evaluation of the effects of a 1:1 inspiratory-to-expiratory ratio in anesthetized and ventilated horses. Veterinary Anaesthesia and Analgesia. ISSN 1467-2987

[img] PDF
Disponible bajo Licencia CC Atribución-NoComercial-SinDerivadas 4.0 Internacional.

Descargar (69kB)

Resumen

Objective: To describe some cardiorespiratory effects of an inspiratory-to-expiratory (IE) ratio of 1:1 compared with 1:3 in ventilated horses in dorsal recumbency. Study design: Randomized crossover experimental study. Animals: A total of eight anesthetized horses, with 444 (330–485) kg body weight [median (range)]. Methods: Horses were ventilated in dorsal recumbency with a tidal volume of 15 mL kg–1 and a respiratory rate of 8 breaths minute–1, and IE ratios of 1:1 (IE1:1) and 1:3 (IE1:3) in random order, each for 25 minutes after applying a recruitment maneuver. Spirometry, arterial blood gases and dobutamine requirements were recorded in all horses during each treatment. Electrical impedance tomography (EIT) data were recorded in four horses and used to generate functional EIT variables including regional ventilation delay index (RVD), a measure of speed of lung inflation, and end-expiratory lung impedance (EELI), an indicator of functional residual capacity (FRC). Results were assessed with linear and generalized linear mixed models. Results: Compared with treatment IE1:3, horses ventilated with treatment IE1:1 had higher mean airway pressures and respiratory system compliance (p < 0.014), while peak, end-inspiratory and driving airway pressures were lower (p < 0.001). No differences in arterial oxygenation or dobutamine requirements were observed. PaCO2 was lower in treatment IE1:1 (p = 0.039). Treatment IE1:1 resulted in lower RVD (p < 0.002) and higher EELI (p = 0.023) than treatment IE1:3. Conclusions and clinical relevance: These results suggest that IE1:1 improved respiratory system mechanics and alveolar ventilation compared with IE1:3, whereas oxygenation and dobutamine requirements were unchanged, although differences were small. In the four horses where EIT was evaluated, IE1:1 led to a faster inflation rate of the lung, possibly the result of increased FRC. The clinical relevance of these findings needs to be further investigated.

Tipo de documento: Artículo
DOI: https://doi.org/10.1016/j.vaa.2022.07.009
Palabras clave: Tomografía. Caballos. Ventilación mecánica.
Temas: Q Ciencia > Q Ciencia (General)
Q Ciencia > QH Historia Natural > QH301 Biología
Unidad académica: Universidad Católica de Córdoba > Facultad de Ciencias Agropecuarias
Google Académico: Citaciones en Google Académico Ver citaciones
URI: http://pa.bibdigital.ucc.edu.ar/id/eprint/3425
Ver item Editar ítem

Descargas mensuales a lo largo de los últimos 12 meses

Producción Académica UCC soporta OAI 2.0 con una URL base http://pa.bibdigital.ucc.edu.ar/cgi/oai2

Sistema de Bibliotecas
Universidad Católica de Córdoba
Campus Universitario. Avenida Armada Argentina 3555
Córdoba, Argentina

Sistema Nacional de Repositorios Digitales (SNRD) EPrints Logo